详细信息

3种方法评价椎动脉型颈椎病大鼠模型     被引量:7

Evaluation of vertebral artery type of cervical spondylosis in rat model with three methods

文献类型:期刊文献

中文题名:3种方法评价椎动脉型颈椎病大鼠模型

英文题名:Evaluation of vertebral artery type of cervical spondylosis in rat model with three methods

作者:巩彦龙[1];宋敏[1];刘涛[1];刘建鸿[1];李清林[1];孙定平[1];董万涛[2]

第一作者:巩彦龙

机构:[1]甘肃中医药大学;[2]甘肃中医药大学附属医院

第一机构:甘肃中医药大学

年份:2016

卷号:37

期号:6

起止页码:497

中文期刊名:暨南大学学报:自然科学与医学版

收录:CSTPCD;;北大核心:【北大核心2014】;CSCD:【CSCD_E2015_2016】;

基金:国家自然科学基金(81360554);甘肃省重点中医药科研立项课题(GZK-2010-Z14);甘肃省中药现代制药工程研究院项目开发(2305083306);甘肃省高等学校研究生导师科研项目(1206-01)

语种:中文

中文关键词:混合造模法;椎动脉型颈椎病;造模评价

外文关键词:hybrid modeling method; cervical spondylosis of vertebral artery type; method of model evaluation

摘要:目的:通过3种方法评价椎动脉型椎颈病模型.方法:将80只Wistar大鼠随机分为空白对照组、植骨压迫法造模组、力学平衡失调法造模组及混合造模法组各20只,通过检测造模前、造模后第2周、第4周颞叶软脑膜微循环血流量、血氧饱和度实验数据的比较,免疫组化检测椎动脉组织中NF-κB表达,评价3种CSA大鼠模型.结果:实验大鼠全部呈现颈椎缩短、偏斜甚至扭曲等椎动脉型颈椎病症状;混合造模法、植骨压迫造模法及力学平衡失调造模法与空白组比较,具有统计学意义(P<0.05);混合造模法分别与植骨压迫造模法及力学平衡失调法比较,具有显著统计学意义(P<0.01).各组大鼠血氧饱和度变化比较无统计学意义(P>0.05),血流量与血氧饱和度无直线相关性(P>0.05).混合造模法椎动脉组织中NF-κB表达最显著(P<0.01).结论:3种造模方法均可成功复制CSA模型,其中以混合造模法较为优异,值得推广.
Aim:To evauate CSA model by three different methods. Methods 80 rats were randomly divided into blank control, bone graft compression module, mechanical balance disorders modeling group and mixed build module group with 30 rats in each, through before modeling, after modeling for second weeks, fourth weeks of temporal lobe cerebral pial microcirculation blood flow, the experimental data of oxygen saturation detection, NF-κB expression in vertebral artery tissue was detected by immunohisto- chemistry, the evaluation model of 3 kinds of CSA rats. Results : show all of the experimental rats presen-ted the symptoms of CSA, such as shortening, deflection and even twisting; Compared with the blank group, the mixed model, bone graft and compression molding method and mechanical equilibrium model, the difference was statistically significant ( P 〈 0. 05 ) . The mixed model method was significantly differ-ent from that of the bone graft compression molding method and mechanical equilibrium (P 〈0. 01) . All groups of rats blood oxygen saturation change is no statistical difference(P 〉0.05) ,no linear correlation between blood flow and blood oxygen saturation ( P 〉 0. 05 ) . NF-κB expression was most prominent in the vertebral artery of the mixed model. Conclusion : The 3 kinds of modeling methods can successfully reproduce the CSA animal model, which is more excellent and worthy of promotion.

参考文献:

正在载入数据...

版权所有©甘肃中医药大学 重庆维普资讯有限公司 渝B2-20050021-8 
渝公网安备 50019002500408号 违法和不良信息举报中心